Select your filters and click the Search button to search for data, or click Clear to clear all filters
 
Logo Main Menu
Mecklenburg County Health Dept
Public Health Inspections
Select your filters and click the Search button to search for data, or click Clear to clear all filters
 
  
 

Premises Information

Return to Inspections
NameLEGETTE BLYTHE ELEMENTARY
Address12202 HAMBRIGHT RD.
 
City/State/ZIP
HUNTERSVILLE NC 28078
Premise Type44 - School Building
CountyMecklenburg
Inspection Date 5/25/2018
Final Score @ Grade
91.50
General CommentsMr. Anthony (custodian) was present during the inspection. Report was emailed to Hilda Collado (head custodian)and the principal. NO POINTS WERE DEDUCTED FOR THE FOLLOWING: 4. Observed the floor surface was damaged with exposed/damp sub floor in RR644 girls restroom. **Floors of toilet facilities shall be impervious and kept clean. 15A NCAC 18A .2408 (c). 8. Observed the ceiling vents were dusty in the cafeteria. **Keep all ventilation equipment clean.

Violations

 
CDI=Corrected During Inspection  R=Repeat Violation  VR=Verification Required 
Violation Item Demerits Violation Description CDIRVRComments
4 35 TOILET FACILITIES: Walls and ceilings clean, nonabsorbent, washable, and in good repair 30#; fixtures clean and in good repair 40#; floors impervious, kept clean 30# (.2408) No No No Walls and ceilings of toilet facilities shall be constructed of non-absorbent, washable materials and shall be kept clean. 15A NCAC 18A .2408 (b). Observed the ceiling was damaged in RR644 men's restroom, wall damaged behind urinals in C hall boys restroom and wall base tile was missing behind the toilet in C hall girls restroom. Toilet fixtures shall be kept clean and in good repair. 15A NCAC 18A .2408 (d). Observed toilets were soiled in RR1210 men's and women's restrooms, a toilet seat was loose in E hall girls restroom, and a toilet was not functioning in C hall boys restroom.
5 35 LAVATORY FACILITIES: Fixtures clean and in good repair 30#; soap and individual towels or approved hand-drying devices provided 40# (.2409) No No No Fixtures shall be kept clean and in good repair. 15A NCAC 18A .2409 (b). Observed sinks were not working in RR1210 boys restroom, and RR644 girls restroom, damaged back splash (not secure on wall and laminate separating due to moisture) in RR1210 boys and girls restrooms. Soap and individual towels or approved hand-drying devices shall be provided. 15A NCAC 18A .2409 (c). Observed no paper towels supplied in D2, D hall boys and girls restrooms
6 15 FLOORS: WALLS: AND CEILINGS: Floors, walls, and ceilings clean and in good repair 30# (.2410) No No No Floors, walls, and ceilings of all areas shall be kept clean and in good repair. 15A NCAC 18A .2410. Observed one ceiling tile was not secure in E6, hallway ceiling tiles leading to the gym/cafeteria with water damage, a repaired wall was not finished with a coat of non-absorbant paint in B6 restroom, 3 missing ceiling tiles due to ceiling leak in A hall, and an unsecured ceiling tile in the nurse's office.