7
|
2
|
Thermometers provided, accurate: .2804, .2807, .2808, .2836 |
No |
No
|
No |
Observed no stem probe thrmometer. Provide.
Provide a numerically scaled metal stem-type thermometer accurate to 2°F. 15A NCAC 18A .2807 (h) |
|
11
|
2
|
Approved sanitizer provided;test kit available: .2809, .2810, .2812, .2814 |
No |
No
|
No |
Observed the sanitizer at 800ppm chlorine.
Prepare a wipe-on or spray-on sanitizer daily at 50 to 200 ppm chlorine. 15A NCAC 18A .2812 (d) |
|
16
|
4
|
Hot water supplied and maintained as required in all other areas: .2815, .2836 |
No |
No
|
No |
Observed the washing machine temp at 105F. Follow the rule below.
Hot water supplied to clothes washing machines shall be 120°F or above. 15A NCAC 18A .2815 (e). |
|
26
|
2
|
Approved cleaning solution and approved disinfectant provided; test kit available when required: .2817, .2818, .2819, .2820, .2836 |
No |
No
|
No |
Observed the disinfectant at above 1000ppm chlorine.
Prepare disinfectant between 500-800 ppm chlorine daily. 15A NCAC 18A .2819 (c ) and .2801 (7). |
|
30
|
3
|
Non-hazardous products properly stored: .2820 |
No |
No
|
No |
Observed the sanitizer and soap bottle unlabeled. Labeled.
All sanitizing solutions shall be labeled with the word "sanitizer". 15A NCAC 18A .2820 (c ). |
|
48
|
3
|
Pest control; premises free of conditions that harbor or attract pests: .2831, .2832 |
No |
No
|
No |
Observed gnats in the restroom.
Keep the facility free of rodents, insects and vermin. 15A NCAC 18A .2831 (b). |