2
|
5
|
Proper handwashing procedure: .2803, .2836 |
No |
No
|
No |
Observed care giver turn off faucet with bare hands.**Handwashing procedure shall include: (1) using liquid soap and tempered water; (2) rubbing hands vigorously with soap and tempered water for 15 seconds; (3) washing all surfaces of the hands, to include the backs of hands, palms, wrists, under fingernailsand between fingers; (4) rinsing well for 10 seconds; (5) drying hands with a paper towel or other hand-drying device; and (6) turning off faucet with a paper towel or other method without recontaminating hands. See rule .2803 (c). |
|
26
|
2
|
Approved cleaning solution and approved disinfectant provided; test kit available when required: .2817, .2818, .2819, .2820, .2836 |
No |
No
|
No |
Observed disinfectant spray bottle in hallway bathroom below 500 ppm chlorine.**Prepare disinfectant between 500-800 ppm chlorine daily. See rule .2819 (c ) and .2801 (7). |
|
46
|
2
|
CCA pressure-treated wood sealed; date sealed_________; soil covered or inaccessible: .2831, .2832 |
No |
No
|
No |
Observed exterior non-painted wood not stained or sealed. **All exterior non-painted wood installed before 1/1/05 must be sealed or stained at least every 2 years. Seal wood with either an oil-based, semi-transparent sealant, oil-based clear stain, or water-based clear stain. Records must be maintained available for review. See rule .2831 (e), (f), and (g). |