14
|
1
|
Required records available: shellstock tags, parasite destruction |
No |
No
|
Yes |
3-203.12 Retain tag on the bag of shellstock until empty. Record date on the tag when the last shellstock from the container is used. Store tags in chronological order for 90 days. -Pf Observed no shellstock tags that have been kept after August 2022 on site. However, facility has regularly sold shellstock over the past 3 months. No tags retained had a date recorded of when the items were sold. VERIFICATION REQUIRED |
|
15
|
0
|
Food separated & protected |
Yes |
No
|
No |
3-302.11 (A)(2) Separate types of raw animal foods from each other such as beef, fish, lamb, pork, and poultry during storage, preparation, holding, and display. -P. Observed comminuted pork sausage stored over lamb in grab and go case. CDI: Items reorganized.
For more information on food storage order please visit: http://meck.co/FoodSafety |
|
22
|
1.50
|
Proper cold holding temperatures |
Yes |
No
|
No |
3-501.16(A)(2) Maintain TCS foods in cold holding at 41F or less. -P Observed items in the far right display case were above 41F. CDI: Items were rapidly cooled. Maintenance was called to fix the case. Items will be cooled in the walk in and then relocated to a working display case. PIC stated that this case has been freezing up so they have been doing extra temperature checks the past few days. |
|
23
|
1.50
|
Proper date marking & disposition |
Yes |
No
|
No |
3-501.18 Discard the food requiring date labels once time/temperature window has expired, if it is not been labeled, or if the label is incorrect. -P Observed ham from 2/2 in the reach in cooler. CDI: Product was voluntarily discarded. Observed no date mark on a second ham in the reach in cooler that employees did not know when it was opened. CDI: Product was voluntarily discarded.
For more information, please visit: http://meck.co/FoodSafety or view our training videos at the following weblinks: What are TCS Foods https://youtu.be/bRvqAETDjQU and Date Marking Food Safely https://youtu.be/BOPsSNUajYs . |
|
48
|
0.50
|
Warewashing facilities: installed, maintained & used; test strips |
No |
No
|
Yes |
4-302.14 Provide a test kit that accurately measures sanitizer concentrations. -Pf Observed inaccurate test strips at the 3-comp sink. Test strips were expired. VERIFICATION REQUIRED |
|
55
|
0
|
Physical facilities installed, maintained & clean |
No |
No
|
No |
6-501.11 Floors, walls, and ceilings including the attachments such as soap and towel dispensers; light fixtures; and heat/ac vents shall be maintained in good repair. Observed missing grout throughout floors. |