22
|
1.50
|
Proper cold holding temperatures |
Yes |
No
|
No |
3-501.16(A)(2) Maintain TCS foods in cold holding at 41F or less. -P Observed several wrapped containers of pig ears and whole chicken cold holding at 52F and 49F in prep area. The ambient air temperature in prep area is 54F. PIC stated items were there for no longer than 2 hours. CDI-PIC relocated items into walk in cooler to rapidly cool.
For more information, please visit: https://health.mecknc.gov/envhealth/food-and-facilities-sanitation or view our training videos at the following weblinks: What are TCS Foods https://youtu.be/bRvqAETDjQU and Safe Food Temperatures https://youtu.be/tXP09IK-1TQ . |
|
35
|
1
|
Approved thawing methods used |
Yes |
Yes
|
No |
3-501.13 (A), (B), (C ) Use approved thawing methods. Pf- Observed several boxes of frozen turkey products ambient thawing prep area. CDI-PIC relocated items back to cooler until ready to be cut. -REPEAT VIOLATION- |
|
38
|
0
|
Insects & rodents not present; no unauthorized animals |
No |
No
|
No |
6-501.111 Keep the premises free of insects, rodents, and other pests. Observed a few small flies at 3 compartment sink and main prep area. Contact pest control for removal of small flies. |
|
41
|
0
|
Wiping cloths: properly used & stored |
No |
No
|
No |
3-304.14(D) Maintain dry wiping cloths free of visible debris and soil. Maintain sanitizer containers for in-use cloths free of visible debris and soil. Observed bloodied wiping cloth with raw food debris stored on prep counter. |
|
45
|
0
|
Single-use & single-service articles: properly stored & used |
Yes |
No
|
No |
4-903.11(A)(C) Store single-use and single-service articles in a clean, dry location; where they are not exposed to splash, dust, or other contamination; and at least 6 inches above the floor. Observed blood and dried meat splatter on single use meat containers and paper towel roll. CDI-PIC discarded items. |
|
55
|
1
|
Physical facilities installed, maintained & clean |
No |
Yes
|
No |
6-101.11/6-201.11 Floors, walls and ceilings shall be designed, constructed, and installed so they are smooth and easily cleanable. Floors shall be non-absorbent in areas subject to moisture. Observed some floor damage in prep area. -REPEAT VIOLATION- |