Select your filters and click the Search button to search for data, or click Clear to clear all filters
 
Logo Main Menu
Mecklenburg County Health Dept
Public Health Inspections
Select your filters and click the Search button to search for data, or click Clear to clear all filters
 
  
 

Premises Information

Return to Inspections
NameCOMPARE FOODS MEAT MARKET
Address818 E ARROWOOD RD
 
City/State/ZIP
CHARLOTTE NC 28217
Premise Type30 - Meat Market
CountyMecklenburg
Inspection Date 3/19/2024
Final Score @ Grade
96 A
General Comments

Violations

 
CDI=Corrected During Inspection  R=Repeat Violation  VR=Verification Required 
Violation Item Demerits Violation Description CDIRVRComments
15 3 Food separated & protected Yes No No 3-302.11(A)(1) Separate raw animal foods from ready-to-eat foods and washed/unwashed fruits and vegetables. -P Observed raw sausage stored above ready-to-eat chicken nuggets in the self-service line. 3-302.11 (A)(2) Separate types of raw animal foods from each other such as beef, fish, lamb, pork, and poultry during storage, preparation, holding, and display. -P. Observed raw chorizo stored above whole muscle steak in the display case. Observed ground beef stored above whole muscle steak in the walk-in cooler. CDI - All items were moved to the correct order.
47 1 Equipment, food & non-food contact surfaces approved, cleanable, properly designed, constructed & used Yes No No 4-501.12 Resurface or replace cutting surfaces that can no longer be effectively cleaned and sanitized. Observed a cutting board behind the display case with deep cuts and stains. 4-402.11 Fixed equipment shall be spaced to allow access for cleaning around the equipment or sealed to adjoining equipment or walls. Observed the 3-comp sink separating from the wall and caulking. Needs to be re-caulked. 4-501.11 Maintain equipment in good repair. Observed the walk-in freezer door with damage at the bottom that is causing a large build-up of ice. Observed missing hose for the sanitizer dispenser for the 3-comp sink. CDI - Employee was able to find a spare hose to attach.
55 0 Physical facilities installed, maintained & clean No No No 6-101.11/6-201.11 Floors, walls and ceilings shall be designed, constructed, and installed so they are smooth and easily cleanable. Floors shall be non-absorbent in areas subject to moisture. Observed the entire floor of the walk-in cooler rusting. Observed low grouting around the tiles next to the 3-comp sink.
56 0 Meets ventilation & lighting requirements; designated areas used No No No 6-202.11 Shield the lights or provide shatter-resistant bulbs in areas of exposed food, equipment, utensils, linens or single-use articles. Observed a non-shatter proof bulb inside of the Chicharron case.