10
|
1
|
Handwashing sinks supplied & accessible |
Yes |
No
|
No |
6-301.12 Provide paper towels or approved alternative for hand drying at each handsink. -Pf Observed no paper towels at hand washing sink. CDI - PIC replace empty machine with paper towels. |
|
47
|
0.50
|
Equipment, food & non-food contact surfaces approved, cleanable, properly designed, constructed & used |
Yes |
No
|
No |
4-501.11 Maintain equipment in good repair. Observed walk in cooler not functioning properly, currently being used for storage of non food items. Facility has other working walk in cooler & walk in freezer.
4-501.11 Maintain equipment in good repair. Observed two hand sinks leaking water from underneath, hose at the 3-comp-sink, and can wash area. CDI - PIC placed work order to have repaired.
4-202.11 Multiuse food contact surfaces shall be smooth, free of open seams, cracks, chips, pits, sharp internal angles, crevices and assembled to allow access to clean. -Pf Observed grey container used for storing raw ground beef with cracks and chips at the bottom. CDI - PIC discarded container. |