17
|
1.50
|
Proper reheating procedures for hot holding |
Yes |
No
|
No |
3-403.11 (C ) Reheat commercially processed, ready-to-eat food to 135F within 2 hours if food is to be hot held until service. -P Observed food employees not reheating product to proper temperature before storing food on hot holding line. Refer to temperature chart. CDI - put product back into the steamer to reheat to proper temperature. Advised to use thermometer more often to monitor temperatures. Product reached proper temperature before hot holding line; currently in compliance. |
|
18
|
0
|
Proper cooling time and temperatures |
Yes |
No
|
No |
3-501.14(B) Quickly cool TCS foods that are prepared from room temperature ingredients. Food must be to 41F within 4 hours. -P Observed chef salads not cooling down in refrigerator. Refer to temperature chart. CDI - pulled chef salads to walkin cooler to rapidly cool down. Educated to prepare product then store in walkin cooler on speed rack to rapidly cool. |
|
31
|
0.50
|
Proper cooling methods used; adequate equipment for temperature control |
Yes |
No
|
No |
3-501.15 Employees shall use proper cooling methods to reach compliance with cooling time and temperature criteria. Observed chef salads cooling down in closed plastic container in refrigerator. CDI - educated to cool down uncovered in walkin cooler. Moved salads to walkin cooler. Product currently in compliance. |
|
45
|
0
|
Equipment, food and non-food-contact surfaces approved; cleanable, properly designed, constructed and used |
No |
No
|
No |
4-501.11 Maintain equipment in good repair. Observed freezer down. Observed product in freezer still in frozen state; technician arrived on site during inspection. Observed torn gasket at hot holding unit. Technician arrived on site during inspection to change out gaskets. CDI. |
|
47
|
0
|
Non-food-contact surfaces clean |
No |
No
|
No |
4-601.11(C )/4-602.13 Non Food-contact surfaces of equipment shall be kept free of an accumulation of dust, dirt, food residue, and other debris. Non food contact surfaces of equipment shall be cleaned at a frequency necessary to preclude accumulation of soil or residue. Observed build up in gaskets. Advised to keep gaskets clean. |
|
53
|
1
|
Physical facilities installed, maintained and clean |
No |