10
|
0
|
Handwashing sinks supplied & accessible |
Yes |
No
|
No |
6-301.12 Provide paper towels or approved alternative for hand drying at each handsink. -Pf Observed no paper towels or other approved alternative for hand drying at hand sink across from dish machine, on front line and next to prep sink. PIC stated they are waiting on supplies. CDI Manager brought more paper towels. |
|
16
|
1.50
|
Food-contact surfaces: cleaned & sanitized |
Yes |
No
|
No |
4-703.11(B) After being cleaned in a mechanical dish machine, equipment food-contact surfaces and utensils shall be sanitized in the dish machine by achieving a utensil surface temperature of 160F as measured by a max/min thermometer.-P. Dish machine is not reaching 160F or above. CDI PIC stated they will utilize 3 comp sink to clean all items until machine can be fixed.
For more information, please visit: https://health.mecknc.gov/envhealth/food-and-facilities-sanitation or view our training video at the following weblink: Cleaning and Sanitizing Food Contact Surfaces https://youtu.be/av1Rbh-lh08 .
4-601.11(A) Equipment food contact surfaces and utensils shall be clean to sight and touch. -Pf. Observed two can openers wit build up on blade. CDI. PIC re washed and sanitized items.
For more information, please visit: https://health.mecknc.gov/envhealth/food-and-facilities-sanitation or view our training videos at the following weblinks: Sanitizing Solutions - https://youtu.be/ykP2mr9CtRg , How to Test Sanitizer https://youtu.be/y0SjmnabFaY , and Cleaning and Sanitizing Food Contact Surfaces https://youtu.be/av1Rbh-lh08 . |
|
54
|
0
|
Garbage & refuse properly disposed; facilities maintained |
No |
No
|
No |
5-501.113(B) Keep dumpster, outside waste containers covered with tight-fitting lids or doors. Observed lid and doors open on dumpster. Lid and doors must remain closed. |
|
55
|
0
|
Physical facilities installed, maintained & clean |
No |
No
|
No |
6-501.11 Floors, walls, and ceilings including the attachments such as soap and towel dispensers; light fixtures; and heat/ac vents shall be maintained in good repair. Observed cracked tiles and tiles with missing pieces throughout facility. Need repair/replacement. |