36
|
0.50
|
Thermometers provided & accurate |
Yes |
No
|
No |
4-502.11(B) Provide accurately calibrated thermometers. Pf. EHS observed high temperature disk malfunctioning during inspection. EHS observed high temperature disk turning off and on at random and capturing a final temperature 30F degrees less than EHS. CDI - PIC retrieved lollipop from office and replaced battery. EHS observed lollipop in good repair and calibrated after battery change. (0.5)
For information on how to properly calibrate a thermometer please visit: https://health.mecknc.gov/envhealth/food-and-facilities-sanitation or view our training video at the following weblink: https://youtu.be/IxXix712KkI |
|
55
|
0
|
Physical facilities installed, maintained & clean |
No |
No
|
No |
6-501.12 Floors, walls, ceilings including the attachments such as soap, towel dispensers; light fixtures; and heat/ac vent covers shall be clean. Caution should be used to minimize food exposure. EHS observed AC vents accumulating a large amount of dust. AC vents are located by the back door. Increase cleaning frequency to avoid accumulation. (0) |