10
|
1
|
Handwashing sinks supplied & accessible |
Yes |
No
|
No |
5-205.11 (A) A handwashing sink shall be maintained so that it is accessible at all times for employee use Pf.
Observed sole handsink in kitchen blocked with mop bucket during inspection,
CDI - Mop bucket relocated.
1 pt. |
|
15
|
0
|
Food separated & protected |
Yes |
No
|
No |
3-302.11(A)(8) Separate unwashed produce from ready-to-eat foods.
Observed unwashed tomatoes being stored above RTE foods in WIC during inspection.
CDI - PIC relocated.
0 pts.
For more information on food storage order please visit: https://health.mecknc.gov/envhealth/food-and-facilities-sanitation |
|
16
|
1.50
|
Food-contact surfaces: cleaned & sanitized |
Yes |
No
|
No |
4-501.114 Maintain sanitizer at correct concentrations when being used to sanitize. -P
4-703.11(B) After being cleaned in a mechanical dish machine, equipment food-contact surfaces and utensils shall be sanitized in the dish machine by achieving a utensil surface temperature of 160F as measured by a max/min thermometer.-P.
Observed sanitizer at two compartment sink holding well below 200pm quat during inspection. PIC stated facility recently acquired new brand of sanitizer. New brand of sanitizer requires far larger amount of product to achieve acceptable concentration. Observed hot water at dish machine achieving a maximum of 157F during inspection. Hot water booster had not been turned on.
CDI - Quat added to two compartment sink to achieve proper concentration. Hot water booster turned on. Hot water achieved maximum of 160F.
1.5 pts.
For more information please visit: https://health.mecknc.gov/envhealth/food-and-facilities-sanitation or view our training videos at the following weblinks: Sanitizing Solutions - https://youtu.be/ykP2mr9CtRg and How to Test Sanitizer https://youtu.be/y0SjmnabFaY
For more information, please visit: https://health.mecknc.gov/envhealth/food-and-facilities-sanitation or view our training video at the following weblink: Cleaning and Sanitizing Food Contact Surfaces https://youtu.be/av1Rbh-lh08 . |
|
48
|
0.50
|
Warewashing facilities: installed, maintained & used; test strips |
No |
No
|
Yes |
4-302.13 (B) Provide an approved Max/Min thermometer for testing sanitizing temperatures in hot water warewashing machines. The thermometer must be readily accessible. -Pf
Observed min/max thermometer on site out of order during inspection. Repair or replacement necessary.
10 day VR required.
0.5 pts. |
|
55
|
0
|
Physical facilities installed, maintained & clean |
No |
No
|
No |
6-501.11 Floors, walls, and ceilings including the attachments such as soap and towel dispensers; light fixtures; and heat/ac vents shall be maintained in good repair.
Observed sealant on floor in WIC chipped and missing. Observed cracked floor tiles in dish pit area during inspection. Repair and/or replacement necessary.
0 pts. |
|
56
|
0
|
Meets ventilation & lighting requirements; designated areas used |
No |
No
|
No |
6-305.11/6-501.110 Designate and use an area for the orderly storage of employees' clothing and possessions.
Observed unopened employee beverage being stored above student beverages in RIC, and employee food stored in conjunction with student food in WIC. Ensure all employee food and beverages are stored in a manner that does not promote contamination of student food and beverages.
0 pts. |