| CDI=Corrected During Inspection | |
R=Repeat Violation | |
VR=Verification Required | |
|
|
| Violation Item
| Demerits
| Violation Description
| CDI | R | VR |
|
|
14
|
1.50
|
Food-contact surfaces: cleaned and sanitized |
Yes |
Yes
|
No |
4-601.11(A) Equipment food contact surfaces and utensils shall be clean to sight and touch. -Pf Observed debris build up on stand mixer in deli/dessert area. Observed sticker residue on containers stored as clean. CDI by removal for recleaning. |
|
35
|
0
|
Food properly labeled: original container |
No |
No
|
No |
3-302.12 Label all working containers of food (oils, spices, salts) except food that is easy to identify such as dry pasta. Observed bottles of different liquids with no labels. |
|
37
|
1
|
Contamination prevented during food preparation, storage and display |
No |
Yes
|
No |
3-305.11 Store food in a clean, dry location, not exposed to contamination. Keep at least 6 inches above the floor. Observed box of food on floor of walk in cooler. |
|
42
|
0.50
|
Utensils, equipment and linens: properly stored, dried and handled |
No |
No
|
No |
4-901.11(A) Air dry equipment and utensils after cleaning and sanitizing. Observed wetstacking and towel drying in the dish area. |
|
45
|
1
|
Equipment, food and non-food-contact surfaces approved; cleanable, properly designed, constructed and used |
No |
Yes
|
No |
4-501.12 Resurface or replace cutting surfaces that can no longer be effectively cleaned and sanitized. Observed deep discolored gouges on cutting surface at pizza flip top.
4-501.11 Maintain equipment in good repair. Observed broken gasket on reach in cooler. |
|
47
|
0
|
Non-food-contact surfaces clean |
No |
No
|
No |
4-601.11(C )/4-602.13 Keep the equipment clean to avoid build up of dust, food residue or debris. Observed debris build up on shelving in walk in cooler. |
|
53
|
0.50
|
Physical facilities installed, maintained and clean |
No |
No
|
No |
6-501.11 Floors, walls, and ceilings including the attachments such as soap and towel dispensers; light fixtures; and heat/ac vents shall be maintained in good repair. Observed damaged floor of walk in cooler. Metal is pulling away from foundation. Attention is required before next inspection. |
|