8
|
0
|
Handwashing sinks, supplied and accessible |
Yes |
No
|
No |
General Comment:
5-205.11 Maintain access to handsinks. Handsinks may only be used for handwashing.-Pf. Observed employee filling pitcher with water at kitchen handsink. CDI: by instruction to use only for handwashing. |
|
13
|
0
|
Food separated and protected |
Yes |
No
|
No |
General Comment: 3-304.15(A) Discard gloves after a task is complete or any time they are damaged or soiled. -P. Observed employee washing gloves after soiled at the kitchen handsink. CDI: gloves were removed and hands were washed properly. |
|
20
|
0
|
Proper cold holding temperatures |
Yes |
No
|
No |
General Comment:
3-501.16(A)(2) Maintain TCS foods in cold holding at 41F or less. -P. Observed inside 3 door cooler sliced turkey at 42F, chili at 42F, queso at 42F, salad mix at 45F, slaw at 44F, tuna salad at 45F, and collard greens at 43F. CDI: through education. NOTE******Highly suggested the addition of a walk-in cooler due to limited cooler space in kitchen to help maintain new cold hold change of 41F/below and to be able to properly cool mutiple TCS foods properly. Facility only has a 3-door reach-in cooler, one 2 door freezer, and a milk box. |
|
21
|
3
|
Proper date marking and disposition |
Yes |
Yes
|
Yes |
Repeat:
3-501.18 Discard the food requiring date labels once time/temperature window has expired, if it is not been labeled, or if the label is incorrect. -P. Observed inside 3-door cooler chub of sliced turkey dated 3.16.19; chili dated 3.14.19; queso dated 3.18.19 all with expired 4 day dates due to temperature. CDI: by voluntary disposal. Observed salad mix prepared yesterday not dated inside 3-door reach-in cooler. Facility must submit and follow Risk Control Plan within 10 days.
VR by 4.7.19 |
|
34
|
0.50
|
Thermometers provided and accurate |
No |
Yes
|
No |
Repeat:
4-204.112 Provide and position correctly an air thermometer in cold/hot holding equipment. Observed thermometer missing from milk box cooler and 3-door reach-in cooler. |
|
52
|
0
|
Garbage and refuse properly disposed; facilities maintained |
No |
No
|
No |
General Comment:
5-501.111 Area, Enclosures and Receptacles, Good Repair - C. Observed back wood part of dumpster enclosure broken. |