21
|
3
|
Proper hot holding temperatures |
No |
Yes
|
No |
Repeat: 3-501.16(A)(1) Maintain TCS foods in hot holding at 135F or above. -P For more information please visit: http://meck.co/FoodSafety or view our training videos at the following weblinks: What are TCS Foods https://youtu.be/bRvqAETDjQU and Safe Food Temperatures https://youtu.be/tXP09IK-1TQ . Observed empanadas hot holding below 135. Observed temperature log posted with multiple dates where empanadas were hot holding below 135F. CDI, items discarded by PIC. Employee states empanadas are for the morning only and are discarded by 10AM. EHS advised PIC to educate staff on hot holding. |
|
22
|
0
|
Proper cold holding temperatures |
Yes |
No
|
No |
3-501.16(A)(2) Maintain TCS foods in cold holding at 41F or less. -P For more information please visit: http://meck.co/FoodSafety or view our training videos at the following weblinks: What are TCS Foods https://youtu.be/bRvqAETDjQU and Safe Food Temperatures https://youtu.be/tXP09IK-1TQ . Observed bag of mozzarella cold holding above 41F. CDI, item discarded by PIC. |
|
39
|
1
|
Contamination prevented during food preparation, storage & display |
Yes |
No
|
No |
6-404.11 Designate a separate area for items that are not for use and are being held for credit, such as dented cans or recalled products. -Pf Observed several dented cans stored on shelve for retail use. CDI, items removed. |
|
45
|
0
|
Single-use & single-service articles: properly stored & used |
No |
No
|
No |
4-903.11(A)(C) Store single-use and single-service articles in a clean, dry location; where they are not exposed to splash, dust, or other contamination; and at least 6 inches above the floor. Observed single use/single service articles stored on floor. Items shall be stored at least 6 inches off the floor. |
|
47
|
0.50
|
Equipment, food & non-food contact surfaces approved, cleanable, properly designed, constructed & used |
No |
Yes
|
No |
Repeat: 4-501.11 Maintain equipment in good repair. Observed damaged door of walk in freezer in back. Need repaired/replaced. |
|
48
|
0
|
Warewashing facilities: installed, maintained & used; test strips |
No |
No
|
Yes |
4-302.14 Provide a test kit that accurately measures sanitizer concentrations. -Pf Observed no test kit for sanitizer at 3 compartment sink. Verification reqiured. |
|
55
|
0.50
|
Physical facilities installed, maintained & clean |
No |
Yes
|
Yes |
Repeat: 6-101.11/6-201.11 Floors, walls and ceilings shall be designed, constructed, and installed so they are smooth and easily cleanable. Floors shall be non-absorbent in areas subject to moisture. Observed absorbent ceiling tiles over prep area. Need replaced.
6-501.11 Floors, walls, and ceilings including the attachments such as soap and towel dispensers; light fixtures; and heat/ac vents shall be maintained in good repair. Observed damaged/missing ceiling tiles where water is leaking through in the front bakery area. Need repaired. Verification required. |