8
|
2
|
Hands clean & properly washed |
Yes |
No
|
No |
2-301.14 (I) Wash hands after engaging in other activities that contaminate hands. -P Employees observed handling cell phones, touching face, and handling money and went back to serving food from steam table. Employees must wash hands after contaminating their hands. CDI - Employees educated and they washed hands. |
|
16
|
1.50
|
Food-contact surfaces: cleaned & sanitized |
Yes |
No
|
No |
4-501.114 Maintain sanitizer at correct concentrations when being used to sanitize. -P Quat sanitizer measured less than 150 ppm. Quat sanitizers shall be 150-400 ppm. CDI - Sanitizer from bottle added to solution until it was 200 ppm. Establishment needs to contact chemical company to repair dispenser.
For more information please visit: https://health.mecknc.gov/envhealth/food-and-facilities-sanitation or view our training videos at the following weblinks: Sanitizing Solutions - https://youtu.be/ykP2mr9CtRg and How to Test Sanitizer https://youtu.be/y0SjmnabFaY |
|
21
|
1.50
|
Proper hot holding temperatures |
Yes |
No
|
No |
3-501.16(A)(1) Maintain TCS foods in hot holding at 135F or above. -P Beef stew and fish measured 115-130F and 120-135F in hot holding. TCS foods in hot holding shall measure at least 135F. CDI - Both items reheated to above 165F.
For more information, please visit: https://health.mecknc.gov/envhealth/food-and-facilities-sanitation or view our training videos at the following weblinks: What are TCS Foods https://youtu.be/bRvqAETDjQU and Safe Food Temperatures https://youtu.be/tXP09IK-1TQ . |
|
44
|
0
|
Utensils, equipment & linens: properly stored, dried & handled |
No |
No
|
No |
4-901.11(A) Air dry equipment and utensils after cleaning and sanitizing. Pans at 3-compartment sink stored as clean were stacked while still wet. Allow utensils to adequately air dry before stacking. 0 pts. |
|
47
|
0
|
Equipment, food & non-food contact surfaces approved, cleanable, properly designed, constructed & used |
No |
No
|
No |
4-501.11 Maintain equipment in good repair. Torn gasket present on walk-in cooler door. Large crack in prep sink needs to be welded. 0 pts. |
|
56
|
0
|
Meets ventilation & lighting requirements; designated areas used |
No |
No
|
No |
6-305.11/6-501.110 Designate and use an area for the orderly storage of employees' clothing and possessions. Employee keys and cell phone observed on prep table. Store employee personal items in a separate location. 0 pts. |