14
|
3
|
Food-contact surfaces: cleaned and sanitized |
Yes |
Yes
|
No |
4-601.11 (A) Equipment, Food-Contact Surfaces, Nonfood-Contact Surfaces, and Utensils - P. Mold build up on 12 soda diffuser nozzles at the self service beverage area. CDI- Operator; Farrukh Mahmood removed all for cleaning. Extra soda nozzles that operator advised were clean, were soaking in a heavily stained bucket that also had dried residue in it. CDI- Operator was advise that the container being used in the cleaning and/ or soaking of the nozzles must also be clean and free of debris. Operator advised that possible residue could be from coffee. CDI- Nozzles and bucket were cleaned.4-501.114 Manual and Mechanical Warewashing Equipment, Chemical Sanitization-Temperature, pH, Concentration and Hardness - P. Quat sanitizer in spray bottle next to alto-shaam at over 400ppm. CDI- sanitizer corrected per label directions to 200ppm for Quat. |
|
37
|
2
|
Contamination prevented during food preparation, storage and display |
Yes |
Yes
|
No |
3-306.11 Food Display-Preventing Contamination by Consumers - P. Apples in display at front counter area not protected from possible contamination by customer. CDI- verbal correction; discussed options with operator for storage and display of apples. |
|
45
|
0
|
Equipment, food and non-food-contact surfaces approved; cleanable, properly designed, constructed and used |
No |
No
|
No |
4-501.11 Good Repair and Proper Adjustment-Equipment - C. Handwashing sink in the back storage area has a very slow drain. Repair. |
|
46
|
0.50
|
Warewashing facilities: installed, maintained and used; test strips |
Yes |
No
|
No |
4-302.14 Sanitizing Solutions, Testing Devices - PF. Both sets of Quat testing strips provided by operator damaged and completely discolored. CDI- operator was able to locate replacement test strips. |
|
52
|
0.50
|
Garbage and refuse properly disposed; facilities maintained |
Yes |
Yes
|
No |
5-501.16 Storage Areas, Rooms and Receptacles, Capacity and Availability - C. No trash receptacle at the handwashing sink in the back room or in the back room at all. Provide a trash receptacle in at the handwashing sink.Comment: 5-501.15 Outside Receptacles - C. One door on the dumpster left open. Keep doors on dumpster closed. |
|
53
|
0
|
Physical facilities installed, maintained and clean |
No |
No
|
No |
6-201.11 Floors, Walls and Ceilings-Cleanability - C. One damaged ceiling tile above the 3 comp sink. Replace ceiling tile. |