22
|
1.50
|
Proper cold holding temperatures |
Yes |
No
|
No |
3-501.16(A)(2) Maintain TCS foods in cold holding at 41F or less. -P Observed quesadilla mix and lettuce in prep cooler above 41F. PIC stated that it was just made at 10 am. EHS educated PIC on cooling TCS foods down to 41F before putting in prep unit cooler. CDI PIC put foods in freezer to quickly cool down.
For more information, please visit: https://health.mecknc.gov/envhealth/food-and-facilities-sanitation or view our training videos at the following weblinks: What are TCS Foods https://youtu.be/bRvqAETDjQU and Safe Food Temperatures https://youtu.be/tXP09IK-1TQ . |
|
40
|
0.50
|
Personal cleanliness |
Yes |
No
|
No |
2-303.11 Remove jewelry on hands and arms while preparing food. A plain ring, such as a wedding band, is allowed. Observed 2 food employees with watches on arm. CDI Employees removed watches
2-402.11 Use head coverings, beard guards and clothing to restrain body hair from contacting exposed food, equipment, and utensils. Observed one employee with no head covering. CDI employee put a hat on. |
|
45
|
0
|
Single-use & single-service articles: properly stored & used |
Yes |
No
|
No |
4-903.11(C ) Single Service and Single Use items shall be kept in the original protective package or stored using other means that protect the item until used. Observed single service trays stored facing up and cups stacked to ceiling outside of plastic. CDI PIC inverted trays and unshackled cups and put them in plastic. |
|
55
|
0
|
Physical facilities installed, maintained & clean |
Yes |
No
|
No |
6-101.11/6-201.11 Floors, walls and ceilings shall be designed, constructed, and installed so they are smooth and easily cleanable. Floors shall be non-absorbent in areas subject to moisture. Observed wall near WIF door with large amount of chipping paint.
6-501.11 Floors, walls, and ceilings including the attachments such as soap and towel dispensers; light fixtures; and heat/ac vents shall be maintained in good repair. Observed missing vent cover in ceiling above prep station. CDI PIC put cover back on |
|
56
|
0
|
Meets ventilation & lighting requirements; designated areas used |
Yes |
No
|
No |
6-403.11 (A)Areas designated for employees to eat and drink, shall be located so that food, equipment, linens, single service/use items are protected from contamination. Observed employee food in WIC on shelf with customer food. Observed employee drink on rack with clean dishes. CDI PIC moved employee items. |