Select your filters and click the Search button to search for data, or click Clear to clear all filters
 
Logo Main Menu
Mecklenburg County Health Dept
Public Health Inspections
Select your filters and click the Search button to search for data, or click Clear to clear all filters
 
  
 

Premises Information

Return to Inspections
NameAUNTIE ANNES PRETZELS
Address11025 CAROLINA PLACE PY
 
City/State/ZIP
PINEVILLE NC 28134
Premise Type2 - Food Stands
CountyMecklenburg
Inspection Date 6/8/2015
Final Score @ Grade
95 A
General Comments

Violations

 
CDI=Corrected During Inspection  R=Repeat Violation  VR=Verification Required 
Violation Item Demerits Violation Description CDIRVRComments
1 2 PIC present, Demonstration - Certification by accredited program, and performs duties No No No 2-101.11 PIC shall be present during all hours of operation.-PF - PIC (Jay) that holds the certification was not present during the inspection.
14 0 Food-contact surfaces: cleaned and sanitized Yes No No General Comment 4-601.11(A) Equipment food contact surfaces and utensils shall be clean to sight and touch. -Pf - Observed a small amount of pink residue in the ice machine. CDI - employee cleaned during inspection.
45 2 Equipment, food and non-food-contact surfaces approved; cleanable, properly designed, constructed and used No Yes No 4-205.10 Ensure equipment other than toasters, mixers, microwaves, water heaters and hoods is ANSI certified or equivalent. - Observed a domestic mini fridge in use under the sink up front. Gaskets are split in the mini fridge. Remove mini fridge. Repeat violation.
49 1 Plumbing installed; proper backflow devices No Yes No 5-205.15 Maintain a plumbing system in good repair.-P - Observed a leak at the back handsink. Repair leak. Repeat violation.
54 0 Meets ventilation and lighting requirements; designated areas used No No No General Comment 6-202.11 Shield the lights or provide shatter-resistant bulbs in areas of exposed food, equipment, utensils, linens or single-use articles. - Observed a missing light shield in the back dry storage room. Replace light shield or replace bulbs with shatter proof bulbs.