8
|
1
|
Handwashing sinks, supplied and accessible |
Yes |
No
|
No |
5-202.12 Provide at least 100F water at handsinks.-Pf
OBSERVED HANDSINKS WITHOUT HOT WATER AT REQUIRED 100F. TEMPERATURES ONLY REACHED 70F. CDI BY REPAIRMAN IMMEDIATELY DIAGNOSING AND REPLACING BLOWN FUSES ON WATER HEATER UNITS.
HOT WATER CHECKED AND READ 101F AND CLIMBING AFTER REPAIRS TO UNITS. |
|
45
|
1
|
Equipment, food and non-food-contact surfaces approved; cleanable, properly designed, constructed and used |
No |
No
|
No |
4-202.16 Nonfood-Contact Surfaces - C
OBSERVED RAW WOOD BASE BOARDS IN WALK-IN COOLER (PRODUCE). SOME WOOD OBSERVED TO HAVE MILDEW AND MOLD PRESENT ON SURFACE.
SEAL RAW WOOD TO MAKE EASILY CLEANABLE AND NON-ABSORBENT.
4-501.11 Maintain equipment in good repair.
OBSERVED SPLIT/TORN GASKET AROUND ICE MACHINE DOOR. REPLACE SPLIT GASKET |
|
47
|
0.50
|
Non-food-contact surfaces clean |
No |
No
|
No |
4-601.11(C )/4-602.13 Keep the equipment clean to avoid build up of dust, food residue or debris.
OBSERVED PINK SLIME ON GASKET SURFACE ON DOOR OF ICE MACHINE. CLEAN |
|
48
|
1
|
Hot and cold water available; adequate pressure |
Yes |
No
|
No |
5-103.11(B) Provide sufficient hot water to meet the peak hot water demands.-Pf
OBSERVED WATER HEATER NOT OPERATING EFFECTIVELY TO PROVIDE HOT WATER AT 100F AT ALL HANDSINKS AND 110F AT WAREWASHING WASH COMPARTMENT.
CDI BY REPAIRMAN IMMEDIATELY DIAGNOSING AND REPLACING BLOWN FUSES ON WATER HEATER UNITS. |
|
53
|
0
|
Physical facilities installed, maintained and clean |
No |
No
|
No |
Floors, walls and ceilings shall be designed, constructed, and installed so they are smooth and easily cleanable.
GENERAL COMMENT
OBSERVED MISSING SIDE PANEL ON BOTTOM DOOR WAY STRUCTURE OF WALK-IN COOLER (PRODUCE). OBSERVED ADHESIVE AND PAPER RESIDUE ON WALL OF 3 COMP SINK, MAKING WALL SURFACE NOT SMOOTH AND EASILY CLEANABLE. REPAIR ALL ITEMS. |