20
|
1.50
|
Proper cooling time & temperatures |
Yes |
No
|
No |
3-501.14(B) Quickly cool TCS foods that are prepared from room temperature ingredients. Food must be to 41F within 4 hours. -P. For more information please visit: http://meck.co/FoodSafety or view our training videos at the following weblinks: What are TCS Foods https://youtu.be/bRvqAETDjQU and Cooling Food Safely https://youtu.be/P6x8b1ZVOxU . Observed salads that were prepared at 9am in the morning still at 44F. CDI- Salads were discarded during the inspection. |
|
22
|
0
|
Proper cold holding temperatures |
Yes |
No
|
No |
3-501.16(A)(2) Maintain TCS foods in cold holding at 41F or less. -P Observed lettuce, salads, and reduced fat milk all holding above 41F threshold. Items were moved to walk in cooler to cool below temperature threshold. |
|
33
|
1
|
Proper cooling methods used; adequate equipment for temperature control |
Yes |
Yes
|
No |
3-501.15 Quickly cool foods. Use methods such as open/vented shallow pans, large ice baths and active stirring. Cold air must flow around product to remove the heat. -Pf For more information please visit: http://meck.co/FoodSafety or view our training videos at the following weblinks: What are TCS Foods https://youtu.be/bRvqAETDjQU and Cooling Food Safely https://youtu.be/P6x8b1ZVOxU .Observed lids attached to salads that did not meet cooling. CDI- Salads were discarded for not meeting cooling time and temperature parameters. |
|
41
|
1
|
Wiping cloths: properly used & stored |
Yes |
Yes
|
No |
3-304.14(B) Hold in-use wiping cloths in properly concentrated sanitizer between uses.
Observed multiple wet cloths stored on counter, Keep in sanitizer buckets. |
|
47
|
0
|
Equipment, food & non-food contact surfaces approved, cleanable, properly designed, constructed & used |
No |
No
|
No |
4-501.11 Maintain equipment in good repair. Observed a number of reach in units not in service due to not working. |
|
51
|
0
|
Plumbing installed; proper backflow devices |
No |
No
|
No |
5-205.15 Maintain a plumbing system in good repair. Observed leak at sprayer faucet above the three comp sink. |
|
55
|
0
|
Physical facilities installed, maintained & clean |
No |
No
|
No |
6-501.12 Floors, walls, ceilings including the attachments such as soap, towel dispensers; light fixtures; and heat/ac vent covers shall be clean. Caution should be used to minimize food exposure. Observed buildup attached to floors and walls. Recommended higher cleaning frequency. |