10
|
1
|
Handwashing sinks supplied & accessible |
Yes |
No
|
No |
6-301.12 Provide paper towels or approved alternative for hand drying at each handsink. -Pf Observed paper towel dispenser inoperable at hand sink upon entry to prep room. CDI: PIC opened paper towel dispenser and cleared jammed paper towels. |
|
44
|
0
|
Utensils, equipment & linens: properly stored, dried & handled |
No |
No
|
No |
4-903.11(B)(1) Clean equipment and utensils shall be stored in a self-draining position that allows for air drying. Observed a stack of metal containers being stored wet nested on clean storage shelf above 3 compartment sink. Store equipment in a position that allows for air drying. |
|
47
|
0
|
Equipment, food & non-food contact surfaces approved, cleanable, properly designed, constructed & used |
No |
No
|
No |
4-501.11 Maintain equipment in good repair. Observed a torn gasket on door of walk in cooler. Replace torn gasket. |