10
|
1
|
Handwashing sinks supplied & accessible |
Yes |
No
|
No |
6-301.12 Provide paper towels or approved alternative for hand drying at each handsink. -Pf Observed paper towel dispenser near fryer and stove not working .Batteries were dead. CDI: Batteries replaced. |
|
22
|
1.50
|
Proper cold holding temperatures |
Yes |
No
|
No |
3-501.16(A)(2) Maintain TCS foods in cold holding at 41F or less. -P For more information please visit: http://meck.co/FoodSafety or view our training videos at the following weblinks: What are TCS Foods https://youtu.be/bRvqAETDjQU and Safe Food Temperatures https://youtu.be/tXP09IK-1TQ . Observed chicken and brisket taquitos in prep top above 41F. CDI: product was rapidly cooled in walk in cooler to below 41F. Do not over stack items that have a lot of air space around them. Consider adding lids to these containers to limit ambient air around the product. |
|
41
|
0
|
Wiping cloths: properly used & stored |
No |
No
|
No |
3-304.14(B) Hold in-use wiping cloths in properly concentrated sanitizer between uses. Observed wet wiping cloth stored on prep top cooler where salsas are held. |
|
43
|
0.50
|
In-use utensils: properly stored |
Yes |
No
|
No |
3-304.12 (E) In-use utensils, such as ice scoops or utensils for non-TCS food, must be stored in a clean and protected location. Observed water and pink build up on interior of ice scoop holder. CDI: Holder and scoop were cleaned. |
|
47
|
0
|
Equipment, food & non-food contact surfaces approved, cleanable, properly designed, constructed & used |
No |
No
|
No |
4-501.11 Maintain equipment in good repair. Observed meat/seafood cage in walk in severely rusted. Observed prep top covers with damaged handles on the cook line. |
|
54
|
0
|
Garbage & refuse properly disposed; facilities maintained |
Yes |
No
|
No |
5-501.113(B) Keep dumpster, outside waste containers covered with tight-fitting lids or doors. Observed doors open on dumpsters. CDI: Doors closed. This is a shared dumpster space. |
|
56
|
0
|
Meets ventilation & lighting requirements; designated areas used |
No |
No
|
No |
6-304.11 Mechanical ventilation of sufficient capacity shall be provided to keep rooms free of excessive heat, steam, condensation, vapors, odors, smoke, and fumes. Observed flat top being used on expo line with oil for warming tortillas for fajitas. This area had significant heat and vapor/smoke distinction compared to the other areas of the expo line. |