16
|
1.50
|
Food-contact surfaces: cleaned & sanitized |
Yes |
No
|
No |
4-601.11(A) Equipment food contact surfaces and utensils shall be clean to sight and touch. -Pf.
Observed multiple pans and containers stored as clean, with food debris present on food contact surfaces.
CDI - Pans were moved to the 3 compartment sink to properly w/r/s properly.
For more information, please visit: https://health.mecknc.gov/envhealth/food-and-facilities-sanitation or view our training videos at the following weblinks: Sanitizing Solutions - https://youtu.be/ykP2mr9CtRg , How to Test Sanitizer https://youtu.be/y0SjmnabFaY , and Cleaning and Sanitizing Food Contact Surfaces https://youtu.be/av1Rbh-lh08 . |
|
28
|
0
|
Toxic substances properly identified stored & used |
Yes |
No
|
No |
7-102.11 Label working containers of toxic materials such as cleaners and sanitizers.-Pf
Observed chemical spray bottle (degreaser) with no label.
CDI - Spray bottle was properly labeled. |
|
41
|
0.50
|
Wiping cloths: properly used & stored |
Yes |
No
|
No |
3-304.14(B) Hold in-use wiping cloths in properly concentrated sanitizer between uses.
Observed sanitizer bucket of sink and surface sanitizer below the required concentration.
CDI - Bucket replaced with sanitizer at the proper strength. |
|
43
|
0
|
In-use utensils: properly stored |
Yes |
No
|
No |
3-304.12 (B) In-use utensils for food that is not TCS must be stored with their handles above the top of the food within containers or equipment that can be closed.
Observed scoop handle submerged in cooked rice.
CDI - Scoop was removed. |
|
44
|
0.50
|
Utensils, equipment & linens: properly stored, dried & handled |
No |
No
|
No |
4-901.11(A) Air dry equipment and utensils after cleaning and sanitizing.
Observed multiple pans stacked wet on multiple drying racks. |
|
47
|
0.50
|
Equipment, food & non-food contact surfaces approved, cleanable, properly designed, constructed & used |
No |
No
|
No |
4-101.19/4-202.16 Non FOOD-CONTACT SURFACES of EQUIPMENT that are exposed to splash, spillage, or other FOOD soiling or that require frequent
cleaning shall be constructed of a CORROSION-RESISTANT, nonabsorbent, and SMOOTH material. NonFOOD-CONTACT SURFACES shall be free of unnecessary ledges, projections, and crevices, and designed and constructed to allow easy cleaning and to facilitate maintenance.
Observed slight rusting on shelving inside the WIC.
4-501.11 Maintain equipment in good repair.
Observed dish machine broken. Work order has been submitted.
EHS will follow-up on dish machine repairs due to the amount of dishes not properly w/r/s. |
|
51
|
0
|
Plumbing installed; proper backflow devices |
No |
No
|
No |
5-205.15 Maintain a plumbing system in good repair.
Observed hand sink near the entrance of the kitchen leaking. In need of repair. |