5
|
0
|
Procedures for responding to vomiting & diarrheal events |
Yes |
No
|
No |
2-501.11 A food establishment shall have written procedures for employees to follow when responding to vomiting or diarrheal events. -Pf For more information please visit: http://meck.co/FoodSafety Observed no vomit/ diarrhea plan. CDI- EHS sent plan via email. |
|
15
|
1.50
|
Food separated & protected |
Yes |
No
|
No |
3-302.11(A)(1) Separate raw animal foods from ready-to-eat foods and washed/unwashed fruits and vegetables. -P For more information on food storage order please visit: http://meck.co/FoodSafety Observed cook chicken stored in front of raw shrimp in the prep top unit. CDI- Cooked chicken removed. |
|
33
|
0.50
|
Proper cooling methods used; adequate equipment for temperature control |
Yes |
No
|
No |
3-501.15 Quickly cool foods. Use methods such as open/vented shallow pans, large ice baths and active stirring. Cold air must flow around product to remove the heat. -Pf For more information please visit: http://meck.co/FoodSafety or view our training videos at the following weblinks: What are TCS Foods https://youtu.be/bRvqAETDjQU and Cooling Food Safely https://youtu.be/P6x8b1ZVOxU . Observed cabbage over stacked in the prep top unit. Observed cooked chicken placed in the prep top unit prior to being cooled to 41F. CDI- Cabbage portioned and chicken placed in the walk in cooler for cooling |
|
49
|
0.50
|
Non-food contact surfaces clean |
No |
Yes
|
No |
4-601.11(C ) Keep non food contact surfaces of equipment clean to avoid build up of dust, food residue or debris.4-602.13 Non food contact surfaces of equipment shall be cleaned frequently to preclude accumulation of soil residues. Observed outside of reach in units in need of cleaning throughout, including freezer from last time. |
|
55
|
0
|
Physical facilities installed, maintained & clean |
No |
No
|
No |
6-501.11 Floors, walls, and ceilings including the attachments such as soap and towel dispensers; light fixtures; and heat/ac vents shall be maintained in good repair. Observed low grout throughout.
6-501.12 Floors, walls, ceilings including the attachments such as soap, towel dispensers; light fixtures; and heat/ac vent covers shall be clean. Caution should be used to minimize food exposure. Observed floors in kitchen area in need of cleaning. Observed walk in freezer floor in need of cleaning. |