| CDI=Corrected During Inspection | |
R=Repeat Violation | |
VR=Verification Required | |
|
|
| Violation Item
| Demerits
| Violation Description
| CDI | R | VR |
|
|
26
|
1
|
Toxic substances properly identified, stored, and used |
Yes |
No
|
No |
7-102.11 Label working containers of toxic materials such as cleaners and sanitizers.-Pf Observed unlabeled spray bottle of degreaser. CDI (corrected during inspection) bottle labeled. |
|
42
|
0.50
|
Utensils, equipment and linens: properly stored, dried and handled |
No |
No
|
No |
4-901.11(A) Air dry equipment and utensils after cleaning and sanitizing. Observed wet stacked metal pans.
4-903.11 Store cleaned equipment, utensils, linens and packages in a clean, dry location and at least 6 inches off the floor. Observed items stored in the office/dry storage room on the floor. |
|
45
|
1
|
Equipment, food and non-food-contact surfaces approved; cleanable, properly designed, constructed and used |
No |
No
|
No |
4-501.11 Maintain equipment in good repair. Observed ice machine repaired with black duct tape where the top ice maker is connected to the bottom bin. New ice machine has been ordered.
Observed blue ice scoop holder cracked as well as some green plastic food container lids. |
|
47
|
0.50
|
Non-food-contact surfaces clean |
No |
No
|
No |
4-601.11(C )/4-602.13 Keep the equipment clean to avoid build up of dust, food residue or debris. Observed the bottom of the slide top bar coolers with build up in the bottom of the coolers, build up on the black soda gun holder at the bar, build up on the outside of the walk-in cooler door and handle, and grease on the gas pipes behind the cook line. |
|
53
|
0.50
|
Physical facilities installed, maintained and clean |
No |
No
|
No |
6-501.12 Floors, walls, ceilings including the attachments such as soap, towel dispensers; light fixtures; and heat/ac vent covers shall be clean. Caution should be used to minimize food exposure. Observed debris and build up on the bar floor behind equipment. Also noted dust on the ceiling around vents over the cook line.
6-201.13 Provide a wall to floor joint that is sealed and coved when flood cleaning methods are used. Floor must be graded to drain to functioning floor drains. Observed broken baseboard tiles on the corner upon entering the kitchen. |
|
54
|
0.50
|
Meets ventilation and lighting requirements; designated areas used |
No |
No
|
No |
6-202.11 Shield the lights or provide shatter-resistant bulbs in areas of exposed food, equipment, utensils, linens or single-use articles. Observed missing light shield over the 3 comp sink. |
|