14
|
1.50
|
Food-contact surfaces: cleaned and sanitized |
No |
No
|
No |
4-602.11 Clean the equipment and utensils used with nonTCS foods as required to avoid contamination. - Observed black build up inside of ice machine. Needs to be cleaned as soon as possible. -1.5pts- |
|
41
|
0
|
In-use utensils: properly stored |
Yes |
No
|
No |
3-304.12 Store in-use utensils in a clean, dry place, in food with handles out, in 135F or greater water or in running water which quickly moves food particles to the drain. - Observed ice scoop handle touching ice. CDI- Scoop was removed. -0pts- |
|
42
|
0
|
Utensils, equipment and linens: properly stored, dried and handled |
No |
No
|
No |
4-901.11(A) Air dry equipment and utensils after cleaning and sanitizing. - Observed several metal pans stored as clean, wet stacked. CDI- Pans were removed. -0pts- |
|
45
|
1
|
Equipment, food and non-food-contact surfaces approved; cleanable, properly designed, constructed and used |
No |
Yes
|
No |
4-501.11 Maintain equipment in good repair. - Observed shelving rusted and peeling in walk-in cooler. Needs to be repaired/replaced. REPEAT. -1pt- |
|
53
|
0.50
|
Physical facilities installed, maintained and clean |
No |
Yes
|
No |
6-201.11 Floors, walls and ceilings shall be designed, constructed, and installed so they are smooth and easily cleanable. - Observed tile busted and broken and can wash area. Needs to be repaired. REPEAT. -0.5pts- |