| Violation Item
| Demerits
| Violation Description
| CDI | R | VR |
|
|
8
|
1
|
Handwashing sinks, supplied and accessible |
Yes |
No
|
No |
6-301.12 Provide paper towels or approved alternative for hand drying at each handsink. -Pf Observed no paper towels at handsink by back door. CDI- Paper towels were provided. |
|
14
|
1.50
|
Food-contact surfaces: cleaned and sanitized |
Yes |
No
|
No |
4-601.11(A) Equipment food contact surfaces and utensils shall be clean to sight and touch. -Pf Observed utensils stored as clean with food debris on them. CDI - Utensils were moved to be cleaned. |
|
31
|
1
|
Proper cooling methods used; adequate equipment for temperature control |
No |
No
|
No |
3-501.15 Quickly cool foods. Use methods such as open/vented shallow pans, large ice baths and active stirring. Cold air must flow around product to remove the heat. -Pf-Observed chicken, beef, and pork cooling in the display cooler tightly covered right after being cut. CDI-PIC uncovered items. |
|
36
|
0
|
Insects and rodents not present; no unauthorized animals |
No |
No
|
No |
6-501.111 Keep the premises free of insects, rodents, and other pests. Observed fly in kitchen. |
|
41
|
1
|
In-use utensils: properly stored |
No |
Yes
|
No |
3-304.12 Store in-use utensils in a clean, dry place, in food with handles out, in 135F or greater water or in running water which quickly moves food particles to the drain. Observed handle of scoop in salt. REPEAT. |
|
47
|
1
|
Non-food-contact surfaces clean |
No |
Yes
|
No |
4-601.11(C )/4-602.13 Keep the equipment clean to avoid build up of dust, food residue or debris. Observed residue and debris built up in microwave and on the windows and gaskets of the display case. REPEAT. |
|
52
|
0
|
Garbage and refuse properly disposed; facilities maintained |
No |
Yes
|
No |
5-501.113(B) Keep dumpster, outside waste containers covered with tight-fitting lids or doors. Observed lid open on dumpster. Dumpsters are shared with other facilities. PIC stated they have reached out to other facilities close by and have asked them to help keep lids and doors closed. PIC stated he will also discuss the issue with the landlord. REPEAT. |
|
53
|
0
|
Physical facilities installed, maintained and clean |
No |
No
|
No |
6-501.11 Floors, walls, and ceilings including the attachments such as soap and towel dispensers; light fixtures; and heat/ac vents shall be maintained in good repair. Observed paper towel dispenser by display cases was broken. |
|
54
|
0
|
Meets ventilation and lighting requirements; designated areas used |
No |
No
|
No |
6-305.11/6-501.110 Designate and use an area for the orderly storage of employees' clothing and possessions. Observed employee jackets and purses stored on shelving with utensils. |