33
|
0.50
|
Approved thawing methods used |
Yes |
No
|
No |
3-501.13 Use approved thawing methods. Observed chicken thawing in prep sink with no running water over it. CDI: Cold water was turned on to flow over chicken as it thawed. |
|
34
|
0.50
|
Thermometers provided and accurate |
No |
No
|
Yes |
4-302.12 Provide an accessible thermometer for use. Provide a thin probe thermometer for accurate measure of thin foods.-Pf Observed that the facility did not have a thin probe thermometer. VERIFICATION REQUIRED. |
|
35
|
0
|
Food properly labeled: original container |
No |
No
|
No |
3-302.12 Label all working containers of food (oils, spices, salts) except food that is easy to identify such as dry pasta. Observed two unlabeled spice containers on the rack above hand sink. |
|
36
|
1
|
Insects and rodents not present; no unauthorized animals |
No |
No
|
No |
6-501.111 Keep the premises free of insects, rodents, and other pests. Observed gnats around the bar area and in the kitchen. |
|
42
|
0.50
|
Utensils, equipment and linens: properly stored, dried and handled |
No |
No
|
No |
4-903.11 Store cleaned equipment, utensils, linens and packages in a clean, dry location and at least 6 inches off the floor. Observed clean utensils stored with the handle down in a plastic container, making it difficult to avoid contaminating the food contact surface.
4-901.11(A) Air dry equipment and utensils after cleaning and sanitizing. Observed metal containers stacked while still wet on the rack above the three compartment sink. |
|
43
|
0
|
Single-use and single-service articles; properly stored and used |
No |
No
|
No |
4-903.11(A) Store single-use and single-service articles to prevent contamination and at least 6 inches off the floor. Observed boxes of single use items stored directly on the roof of walk in cooler. |
|
53
|
0
|
Physical facilities installed, maintained and clean |
No |
No
|
No |
6-201.11 Floors, walls and ceilings shall be designed, constructed, and installed so they are smooth and easily cleanable. Observed missing ceiling tiles over soup and fryer area.
6-501.12 Floors, walls, ceilings including the attachments such as soap, towel dispensers; light fixtures; and heat/ac vent covers shall be clean. Caution should be used to minimize food exposure. Observed dust build up on fans in the walk in cooler. Observed vent covers and tiles also in need of cleaning. |