NameHAWTHORNE`S NY PIZZA & BAR #3
Address4100 CARMEL RD
 
City/State/ZIP
CHARLOTTE NC 28226
Premise Type1 - Restaurant
CountyMecklenburg
Inspection Date 12/15/2022
Final Score @ Grade
98 A
General Comments

Violations

 
CDI=Corrected During Inspection  R=Repeat Violation  VR=Verification Required 
Violation Item Demerits Violation Description CDIRVRComments
33 0.50 Proper cooling methods used; adequate equipment for temperature control Yes Yes No 3-501.15 Quickly cool foods. Use methods such as open/vented shallow pans, large ice baths and active stirring. Cold air must flow around product to remove the heat. -Pf For more information please visit: http://meck.co/FoodSafety or view our training videos at the following weblinks: What are TCS Foods https://youtu.be/bRvqAETDjQU and Cooling Food Safely https://youtu.be/P6x8b1ZVOxU . Observed recently prepared spaghetti portioned and bagged inside of the walk in cooler. Ensure that foods are being cooled properly before tightly bagging or bags are left open in order to vent and cool at a faster rate.CDI- Spaghetti was vented and placed inside of walk in freezer.
37 1 Food properly labeled: original container Yes Yes No 3-302.12 Label all working containers of food (oils, spices, salts, flour, sugar) except food that is easy to identify such as dry pasta. Observed bulk container of oils not labeled. CDI- Labeled during the inspection.
45 0.50 Single-use & single-service articles: properly stored & used Yes Yes No 4-903.11(C ) Single Service and Single Use items shall be kept in the original protective package or stored using other means that protect the item until used. Observed single service trays stored open-ended allowing possible contamination by splash or the landing of flies. CDI-Single service trays were inverted during the inspection.