Select your filters and click the Search button to search for data, or click Clear to clear all filters
 
Logo Main Menu
Mecklenburg County Health Dept
Public Health Inspections
Select your filters and click the Search button to search for data, or click Clear to clear all filters
 
  
 

Premises Information

Return to Inspections
NamePANDA EXPRESS #1252
Address101 SENECA PL
 
City/State/ZIP
CHARLOTTE NC 28210
Premise Type1 - Restaurant
CountyMecklenburg
Inspection Date 2/21/2023
Final Score @ Grade
98 A
General Comments

Violations

 
CDI=Corrected During Inspection  R=Repeat Violation  VR=Verification Required 
Violation Item Demerits Violation Description CDIRVRComments
41 0.50 Wiping cloths: properly used & stored Yes Yes No REPEAT: 3-304.14(B) Hold in-use wiping cloths in properly concentrated sanitizer between uses. Observed sanitizer solution registering at 50 PPM quaternary. CDI - Sanitizer remade and solution now registering at 200 ppm. -0.5-
44 0 Utensils, equipment & linens: properly stored, dried & handled Yes No No 4-901.11(A) Air dry equipment and utensils after cleaning and sanitizing. Dishes shall be stored in a manner that allows them to effectively air dry. Observed plastic containers left wet stacked during the inspection. CDI - Utensils separated to allow proper air drying. Food establishment shall implement pyramid stacking method in the future to allow air flow and effective air drying dishes. -0-
47 0.50 Equipment, food & non-food contact surfaces approved, cleanable, properly designed, constructed & used No Yes No REPEAT: 4-501.11 Maintain equipment in good repair. Observed damaged gaskets on upright reach-in unit. Door unable to self close. Observed walk-in cooler door unable to self close. Repair.
49 0 Non-food contact surfaces clean No No No 4-601.11(C) Keep non food contact surfaces of equipment clean to avoid build up of dust, food residue or debris. 4-602.13 Non food contact surfaces of equipment shall be cleaned frequently to preclude accumulation of soil residues. Observed thorough cleaning needed behind beverage machines in lobby. -0-
51 1 Plumbing installed; proper backflow devices No No Yes 5-202.14 Prevent backflow or back siphonage prevention devices installed shall meet American Society of Sanitary Engineering standards. - P. Observed missing backflow prevention device at canwash in back of kitchen. -1- 5-205.15 Maintain a plumbing system in good repair. Observed active leaking at main valve below wok station, causing water to pool on floor. Repairs needed. ***3-DAY VERIFICATION REQUIRED FOR BACKFLOW DEVICE.
56 0 Meets ventilation & lighting requirements; designated areas used Yes No No 6-305.11/6-501.110 Designate and use an area for the orderly storage of employees' clothing and possessions. Observed personal cell phone on prep counter. CDI - Device removed. -0-