NameANGRY ALES
Address1518 MONTFORD DR
 
City/State/ZIP
CHARLOTTE NC 28209
Premise Type1 - Restaurant
CountyMecklenburg
Inspection Date 10/27/2016
Final Score @ Grade
97 A
General Comments

Violations

 
CDI=Corrected During Inspection  R=Repeat Violation  VR=Verification Required 
Violation Item Demerits Violation Description CDIRVRComments
4 0 Proper eating, tasting, drinking, or tobacco use Yes No No 2-401.11 Cover and store employee drinks to prevent contamination of food or utensils. Observed one employee beverage stored over dry goods on a dry storage rack in the kitchen. Beverage was relocated during inspection.
20 1.50 Proper cold holding temperatures Yes Yes No 3-501.16(A)(2) Maintain TCS foods in cold holding at 45F or less. -P Observed cheese slices cold holding above 45F in a flip top cooler (see temp. chart). CDI- items were relocated to the walk in cooler for cooling. Minor improvements to cold holding since last inspection.
31 1 Proper cooling methods used; adequate equipment for temperature control Yes Yes No 3-501.15 Quickly cool foods. Use methods such as open/vented shallow pans, large ice baths and active stirring. Cold air must flow around product to remove the heat. -Pf Observed macaroni noodles cooling in the walk in cooler in a large, lidded cambro (~5 gallons). CDI- product was split into two containers and had ice and water added to it for more effective cooling.
41 0.50 In-use utensils: properly stored No No No 3-304.12 Store in-use utensils in a clean, dry place, in food with handles out, in 135F or greater water or in running water which quickly moves food particles to the drain. Observed 2 knives being stored in-between the flip top cooler equipment gap when not in use.
53 0 Physical facilities installed, maintained and clean No No No 6-501.11 Floors, walls, and ceilings including the attachments such as soap and towel dispensers; light fixtures; and heat/ac vents shall be maintained in good repair. Observed damaged / pitted asphalt outside the back door of the facility. 6-502.12 Floors, walls, ceilings including the attachments such as soap, towel dispensers; light fixtures; and heat/ac vent covers shall be clean. Caution should be used to minimize food exposure. Observed splash debris on the wall in the kitchen nearest the reach in freezers.