21
|
1.50
|
Proper date marking and disposition |
Yes |
No
|
No |
3-501.17 Date mark/label all TCS foods that are ready-to-eat once opened or prepared and held more than 24hrs. -Pf Observed front prep line with no date marks, date marks were placed on items that were in fridge that were correlated but date needs to follow item. CDI-PIC got food employee to datemark |
|
31
|
0.50
|
Proper cooling methods used; adequate equipment for temperature control |
Yes |
No
|
No |
3-501.15 Quickly cool foods. Use methods such as open/vented shallow pans, large ice baths and active stirring. Cold air must flow around product to remove the heat. -Pf Observed shrimp in cold drawer at 53F heavily wrapped and ice placed on top. Item needs to be placed in walk-in to cool down properly after prep. CDI-PIC took to walk-in cooler to cool down |
|
42
|
0.50
|
Utensils, equipment and linens: properly stored, dried and handled |
No |
No
|
No |
4-901.11(A) Air dry equipment and utensils after cleaning and sanitizing. Observed wet stacking in drying area, was not aggressious. Repeat violation. G |
|
45
|
0
|
Equipment, food and non-food-contact surfaces approved; cleanable, properly designed, constructed and used |
No |
No
|
No |
4-501.11 Maintain equipment in good repair. Observed old ice machine damaged and taped. Hot holding unit isn't being used for storage. |
|
47
|
0
|
Non-food-contact surfaces clean |
No |
No
|
No |
4-601.11(C )/4-602.13 Keep the equipment clean to avoid build up of dust, food residue or debris. Observed backsplash on soda machine heavily soiled. |
|
53
|
0
|
Physical facilities installed, maintained and clean |
No |
No
|
No |
6-501.11 Repairing-Premises, Structures, Attachments, and Fixtures-Methods - C Shelf was broken, discharge pipe needs a cover, ceiling tile missing by new ice machine, broken tiles by new ice macine. |