2
|
1
|
Certified Food Protection Manager |
No |
No
|
No |
2-102.12 (A) PIC shall demonstrate knowledge by being a certified food protection manager.
Observed no CFPM onsite during inspection. PIC stated trainings have been put on schedule.
For more information on becoming a certified food protection manager please visit: www.mecknc.gov/foodsafety |
|
16
|
0
|
Food-contact surfaces: cleaned & sanitized |
Yes |
No
|
No |
4-501.114 Maintain sanitizer at correct concentrations when being used to sanitize. -P. Observed quat solution in 3-comp sink below 150ppm while actively sanitizing dishes. CDI- PIC emptied sink and replaced solution to above 200ppm. Began process of changing out low bag.
For more information please visit: https://health.mecknc.gov/envhealth/food-and-facilities-sanitation or view our training videos at the following weblinks: Sanitizing Solutions - https://youtu.be/ykP2mr9CtRg and How to Test Sanitizer https://youtu.be/y0SjmnabFaY |
|
38
|
0
|
Insects & rodents not present; no unauthorized animals |
No |
No
|
No |
6-501.111 Keep the premises free of insects, rodents, and other pests.
Observed a live crawling insect and a live flying insect. EHS discussed pest control measures with PIC. |
|
47
|
0
|
Equipment, food & non-food contact surfaces approved, cleanable, properly designed, constructed & used |
No |
No
|
No |
4-501.11 Maintain equipment in good repair.
Observed walk-in freezer with heavy ice buildup on pipes. Unit was functioning properly at time of inspection.
Observed 2-door reach-in freezer with water droplets forming on fan. Directly over packaged foods. |
|
49
|
1
|
Non-food contact surfaces clean |
No |
Yes
|
No |
4-601.11(C ) Keep non food contact surfaces of equipment clean to avoid build up of dust, food residue or debris.4-602.13 Non food contact surfaces of equipment shall be cleaned frequently to preclude accumulation of soil residues. Observed soda machine and nozzles, bottom of reach in freezer, areas on and around holding equipment and cooking equipment, all needing cleaning. *REPEAT* |
|
51
|
0
|
Plumbing installed; proper backflow devices |
No |
No
|
No |
5-205.15 Maintain a plumbing system in good repair.
Observed back drain under 3-comp needing to be clean and unclogged. |
|
55
|
1
|
Physical facilities installed, maintained & clean |
No |
Yes
|
No |
6-501.12 Floors, walls, ceilings including the attachments such as soap, towel dispensers; light fixtures; and heat/ac vent covers shall be clean. Caution should be used to minimize food exposure. Observed facility needing cleaning in hard to reach places under equipment. Walls in establishment with residue accumulation needing cleaning. *REPEAT* |