20
|
1.50
|
Proper cold holding temperatures |
Yes |
Yes
|
No |
3-501.16(A)(2) Maintain TCS foods in cold holding at 45F or less. -P Observed ginger mayo holding at 60F in flip top unit across from hot holding cabinets. CDI: Ginger mayo placed on TPHC and PIC changed procedure to keep mayo based dressings in reach in unit beneath flip top. REPEAT. Facility has demonstrated excellent cold holding compliance throughout kitchen and since only one item was observed out of temperature, points were not escalated. |
|
31
|
0.50
|
Proper cooling methods used; adequate equipment for temperature control |
Yes |
Yes
|
No |
3-501.15 Quickly cool foods. Use methods such as open/vented shallow pans, large ice baths and active stirring. Cold air must flow around product to remove the heat. -Pf Observed cole slaw in walk in unit cooling at 48F in a covered plastic bin. CDI: Product vented to facilitate rapid cooling. REPEAT. |
|
41
|
0
|
In-use utensils: properly stored |
Yes |
No
|
No |
3-304.12 Store in-use utensils in a clean, dry place, in food with handles out, in 135F or greater water or in running water which quickly moves food particles to the drain. Observed in use utensils held in water at 118F. |
|
43
|
0
|
Single-use and single-service articles; properly stored and used |
Yes |
No
|
No |
4-904.11 Display and handle single-use and single-service articles to prevent contamination. Observed single service take out boxes displayed throughout facility with food contact surface facing up. |