2
|
1
|
Certified Food Protection Manager |
No |
No
|
No |
2-102.12 PIC shall demonstrate knowledge by being a certified food protection manager. For more information on becoming a certified food protection manager please visit: http://meck.co/FoodSafety. Observed no CFPM on site during inspection. - 1 - |
|
22
|
1.50
|
Proper cold holding temperatures |
Yes |
No
|
No |
3-501.16(A)(2) Maintain TCS foods in cold holding at 41F or less. -P For more information please visit: http://meck.co/FoodSafety or view our training videos at the following weblinks: What are TCS Foods https://youtu.be/bRvqAETDjQU and Safe Food Temperatures https://youtu.be/tXP09IK-1TQ . Observed milk, sweet cream, half n half, coconut milk, whipped cream, and almond milk stored in cooler reading 46F. Ambient temp of cooler reading 45F. CDI - All Milks moved to various coolers to cool down and store. All milks have been stored for less than 4 hours in cooler. - 1.5 - |
|
33
|
0.50
|
Proper cooling methods used; adequate equipment for temperature control |
No |
No
|
Yes |
4-301.11 Provide equipment in number and capacity so that cooling, heating, and holding temperatures are achieved. -Pf Observed reach in unit on serve line reading 45F. Unit is required for adequate cold holding for facility. A VR will occur no later than 6/17/2022 to ensure unit has been repaired. - 0.5 - |
|
36
|
0.50
|
Thermometers provided & accurate |
No |
No
|
Yes |
4-302.12 Provide an accessible thermometer for use. Provide a thin probe thermometer for accurate measure of thin foods.-Pf . For information on how to properly calibrate a thermometer please visit: http://meck.co/FoodSafety or view our training video at the following weblink: https://youtu.be/IxXix712KkI Observed no thermometer present during inspection. PIC states thermometer has been purchased. A VR will occur no later than 6/17/2022 to ensure thin probe thermometer is purchased. - 0.5 - |
|
41
|
0
|
Wiping cloths: properly used & stored |
Yes |
No
|
No |
3-304.14(B) Hold in-use wiping cloths in properly concentrated sanitizer between uses. Observed sanitizer container reading 50ppm QUAT sanitizer. CDI - Container was refilled to 200ppm. - 0 - |
|
45
|
0.50
|
Single-use & single-service articles: properly stored & used |
No |
Yes
|
No |
4-903.11(A)(C) Store single-use and single-service articles in a clean, dry location; where they are not exposed to splash, dust, or other contamination; and at least 6 inches above the floor. Observed drink trays and to go bags stored on floor near cold brew station. Maintain items at least 6 inches off of floor. - REPEAT - 0.5 - |
|
48
|
0
|
Warewashing facilities: installed, maintained & used; test strips |
No |
Yes
|
No |
4-302.13 (B) Provide an approved Max/Min thermometer for testing sanitizing temperatures in hot water warewashing machines. The thermometer must be readily accessible. -Pf Observed no max/min thermometer capable of testing high temp dish machine. - 0 - |