26
|
1
|
Toxic substances properly identified, stored, and used |
Yes |
No
|
No |
7-102.11 Label working containers of toxic materials such as cleaners and sanitizers.-Pf Observed generic chemical bottle without label stating what is inside near restrooms. Observed rubbed off label on sanitizer bucket near prep sink. CDI - PIC labeled these during inspection. -1- |
|
37
|
1
|
Contamination prevented during food preparation, storage and display |
No |
Yes
|
No |
3-305.11 Store food in a clean, dry location, not exposed to contamination. Keep at least 6 inches above the floor. Observed bottled water stored directly on floor in cage in dining room. Observed food stored on low riser at 4 inches off ground in walk in cooler. REPEAT -1- |
|
42
|
0.50
|
Utensils, equipment and linens: properly stored, dried and handled |
No |
Yes
|
No |
4-901.11(A) Air dry equipment and utensils after cleaning and sanitizing. Observed wet nested drinking cups in dining room. -.5- bar |
|
49
|
0
|
Plumbing installed; proper backflow devices |
Yes |
No
|
No |
5-205.15 Maintain a plumbing system in good repair. Observed slow drain at first handsink inside the inspection. -0- |
|
53
|
1
|
Physical facilities installed, maintained and clean |
No |
Yes
|
No |
6-501.11 Floors, walls, and ceilings including the attachments such as soap and towel dispensers; light fixtures; and heat/ac vents shall be maintained in good repair. Observed broken floor tiles near toilets and urinals in restroom. Observed cracked floor tiles throughout dish pit. -1- |