| Violation Item
| Demerits
| Violation Description
| CDI | R | VR |
|
|
14
|
0
|
Food-contact surfaces: cleaned and sanitized |
No |
No
|
No |
4-602.11 Clean the equipment and utensils used with nonTCS foods as required to avoid contamination. Dark build up inside of tea nozzles. Clean nozzles. |
|
22
|
1
|
Time as a Public Health Control: procedures and records |
Yes |
No
|
No |
3-501.19 Provide and follow written procedures for foods held using Time as a Public Health Control (TPHC). Clearly mark foods with begin and end times. All food not sold by the end of 4 hours shall be discarded. -P/Pf Fries on TPHC not covered with deli paper as required by TPHC procedure. CDI - Fries discarded and new batch started. |
|
41
|
0
|
In-use utensils: properly stored |
No |
No
|
No |
3-304.12 Store in-use utensils in a clean, dry place, in food with handles out, in 135F or greater water or in running water which quickly moves food particles to the drain. Tongs stored with handle touching fries. CDI - Tongs removed. |
|
45
|
2
|
Equipment, food and non-food-contact surfaces approved; cleanable, properly designed, constructed and used |
No |
Yes
|
No |
4-501.11 Maintain equipment in good repair. Chipping paint and rust on shelves in chicken walk in cooler. Replace as needed. Repeat violation. |
|
46
|
0.50
|
Warewashing facilities: installed, maintained and used; test strips |
No |
No
|
Yes |
4-302.14 Provide a test kit that accurately measures sanitizer concentrations. Test strips are missing concentration chart, expiration date, and apprear to have gotten wet as they are discolored. VR - Will return within 10 days to verify correction. |
|
47
|
1
|
Non-food-contact surfaces clean |
No |
Yes
|
No |
4-601.11(C )/4-602.13 Keep the equipment clean to avoid build up of dust, food residue or debris. Clean build up from walk in cooler shelves, cooler doors, door handles, and surfaces of equipment throughout. Repeat violation. |
|
49
|
0
|
Plumbing installed; proper backflow devices |
No |
No
|
No |
5-205.15 Maintain a plumbing system in good repair. Waste water splashing out of floor drain under three comp sink when basins are drained. Adjust drain line under three comp sink to dispense water towards the center of the floor drain. |
|
52
|
0.50
|
Garbage and refuse properly disposed; facilities maintained |
No |
No
|
No |
5-501.115 Discard items and litter stored in the waste areas and enclosures as they are not necessary to operation and maintenance. 5-501.113(B) Keep dumpster, outside waste containers covered with tight-fitting lids or doors. Close dumpster doors and clean up debris on ground around dumpster. |
|
53
|
1
|
Physical facilities installed, maintained and clean |
No |
Yes
|
No |
6-501.11 Floors, walls, and ceilings including the attachments such as soap and towel dispensers; light fixtures; and heat/ac vents
shall be maintained in good repair. Repair floors with missing grouting between floor tiles, especially in front of dish area. 6-502.12 Floors, walls, ceilings including the attachments such as soap, towel dispensers; light fixtures; and heat/ac vent covers shall be clean. Caution should be used to minimize food exposure. Clean floors throughout. |