10
|
0
|
Handwashing sinks supplied & accessible |
No |
No
|
No |
5-205.11 (A) A handwashing sink shall be maintained so that it is accessible at all times for employee use Pf. Observed stacked buckets blocking access to handsink. CDI - PIC instructed employee to move buckets to restore access to handsink. -0- |
|
21
|
1.50
|
Proper hot holding temperatures |
Yes |
No
|
No |
3-501.16(A)(1) Maintain TCS foods in hot holding at 135F or above. -P Observed Gorgonzola cream sauce hot holding at 126F in hot unit that was not turned on. Other items in hot holding unit were 135F or more. CDI - PIC reheated to 178F after turning on hot unit. Foods will be monitored to ensure proper hot holding. -1.5-
For more information, please visit: www.mecknc.gov/foodsafety or view our training videos at the following weblinks: What are TCS Foods https://www.youtube.com/watch?v=q0iLZb7v0UM and Safe Food Temperatures https://youtu.be/tXP09IK-1TQ . |
|
33
|
0.50
|
Proper cooling methods used; adequate equipment for temperature control |
Yes |
No
|
No |
3-501.15 Quickly cool foods. Use methods such as open/vented shallow pans, large ice baths and active stirring. Cold air must flow around product to remove the heat. -Pf Observed corn soup cooling in large container with lid snapped on at 43F and still at 43F after 35 minutes. This was a 0F change in temperature. CDI - PIC removers lid and used ice wand to cool. -.5-
For more information, please visit: https://health.mecknc.gov/envhealth/food-and-facilities-sanitation or view our training videos at the following weblinks: What are TCS Foods https://youtu.be/bRvqAETDjQU and Cooling Food Safely https://youtu.be/P6x8b1ZVOxU . |
|
37
|
0
|
Food properly labeled: original container |
No |
No
|
No |
3-302.12 Label all working containers of food (oils, spices, salts, flour, sugar) except food that is easy to identify such as dry pasta. Observed larger bins of dry goods not labeled. CDI - PIC labeled. -0- |
|
47
|
1
|
Equipment, food & non-food contact surfaces approved, cleanable, properly designed, constructed & used |
No |
Yes
|
No |
4-501.11 Maintain equipment in good repair. Observed rusted shelves in prep unit to left of cook line. Repair. REPEAT -1- |
|
51
|
0
|
Plumbing installed; proper backflow devices |
No |
No
|
No |
5-205.15 Maintain a plumbing system in good repair. Observed cold water faucet handle stripped and soap not turning off at 3-comp sink. Repair. -0- |
|
56
|
0
|
Meets ventilation & lighting requirements; designated areas used |
No |
No
|
No |
6-304.11 Mechanical ventilation of sufficient capacity shall be provided to keep rooms free of excessive heat, steam, condensation, vapors, odors, smoke, and fumes. Observed tabletop fryer in use without ventilation/hood. Discussed with PIC possibly moving to space under hood on top of prep table. -0- |