6
|
2
|
Hands clean and properly washed |
Yes |
No
|
No |
2-301.14 (G) Wash hands after handling soiled equipment or utensils and before food preparation, handling clean equipment and utensils and unwrapped single-use/single-service articles. -P Observed food employee cracking and cooking raw shelled eggs that are not pasteurized and then resume plating and handling RTE foods without handwashing. CDI - PIC educated staff about when to wash hands. Hands washed. -2- |
|
7
|
1.50
|
No bare hand contact with RTE foods or a pre-approved alternate properly followed |
Yes |
No
|
No |
3-301.11(B) Do not contact exposed ready-to-eat food with bare hands. Use suitable utensils, single-use gloves or dispensing equipment. -P Observed food employee hand dispensing RTE cheese into grits and into omelet without wearing gloves, using tongs or other means to prevent bare hand contact with RTE food. CDI - PIC cooked all foods to above 165F. -1.5- |
|
22
|
1
|
Time as a Public Health Control: procedures and records |
Yes |
No
|
No |
3-501.19 Provide and follow written procedures for foods held using Time as a Public Health Control (TPHC). Clearly mark foods with begin and end times. All food not sold by the end of 4 hours shall be discarded. -P/Pf Observed eggs declared held on TPHC without written procedure to ensure TCS foods do not stay at room temperature longer than four hours. CDI - PIC filled out procedure today during inspection. Have procedure available during all future inspections. -0- |
|
34
|
0
|
Thermometers provided and accurate |
No |
No
|
No |
4-203.12 (B) Ambient air and water thermometers shall be accurate.-Pf Observed ambient air thermometer in reach in cooler nearest front counter reading 45F and ambient air inside is 36F as verified by EHS thermometer. CDI - PIC inserted accurate ambient air thermometer during inspection. -0- |
|
53
|
0
|
Physical facilities installed, maintained and clean |
No |
No
|
No |
6-101.11 (A)(3) Surface Characteristics-Indoor Areas - C Toilet room floors, walls and ceilings shall be nonabsorbent. Observed absorbent ceiling tiles in restrooms. -0- |