| Violation Item
| Demerits
| Violation Description
| CDI | R | VR |
|
|
2
|
1
|
Certified Food Protection Manager |
No |
Yes
|
No |
2-102.12 (A) PIC shall demonstrate knowledge by being a certified food protection manager. Observed no CFPM on duty. REPEAT
For more information on becoming a certified food protection manager please visit: https://health.mecknc.gov/envhealth/food-and-facilities-sanitation |
|
16
|
1.50
|
Food-contact surfaces: cleaned & sanitized |
No |
Yes
|
No |
4-602.11 (E )Clean the equipment and utensils used with nonTCS foods as required to avoid contamination. Observed buildup on shield in ice machine. REPEAT |
|
28
|
0
|
Toxic substances properly identified stored & used |
Yes |
No
|
No |
7-201.11 Store toxic materials to avoid contamination of food, equipment, utensils, linens, and single-service/use items. -P Observed sanitize bucket on top of front prep top. CDI PIC moved sanitizer bucket. |
|
40
|
0
|
Personal cleanliness |
No |
No
|
No |
2-303.11 Remove jewelry on hands and arms while preparing food. A plain ring, such as a wedding band, is allowed. Observed kitchen employee with jewelry on his arm. CDI Employee removed jewelry.
2-402.11 Use head coverings, beard guards and clothing to restrain body hair from contacting exposed food, equipment, and utensils. Observed employees with no head covering and no beard guards on. |
|
43
|
0
|
In-use utensils: properly stored |
No |
No
|
No |
3-304.12 (E) In-use utensils, such as ice scoops or utensils for non-TCS food, must be stored in a clean and protected location. Observed scooper for ice stored unprotected on top of ice machine. |
|
47
|
1
|
Equipment, food & non-food contact surfaces approved, cleanable, properly designed, constructed & used |
No |
Yes
|
No |
4-501.11 Maintain equipment in good repair. Observed gasket on Fish lowboy cooler torn. REPEAT |
|
49
|
1
|
Non-food contact surfaces clean |
No |
Yes
|
No |
4-601.11(C ) Keep non food contact surfaces of equipment clean to avoid build up of dust, food residue or debris.4-602.13 Non food contact surfaces of equipment shall be cleaned frequently to preclude accumulation of soil residues. Observed large amount of black buildup on gasket of WIC door. REPEAT |
|
51
|
1
|
Plumbing installed; proper backflow devices |
No |
No
|
No |
5-202.14 Prevent backflow or back siphonage prevention devices installed shall meet American Society of Sanitary Engineering standards. -P Observed hose attached at mop sink faucet, and laying on floor of mop sink, with no back flow preventer installed. VR needed 3-13-24 |
|
55
|
0
|
Physical facilities installed, maintained & clean |
Yes |
No
|
No |
6-101.11/6-201.11 Floors, walls and ceilings shall be designed, constructed, and installed so they are smooth and easily cleanable. Floors shall be non-absorbent in areas subject to moisture. Observed cardboard on the floor of the WIF. CDI PIC removed cardboard. |